Medidor de fluxo de gás robusto para gás natural, GLP, medição de fluxo de biogás.Inquiry Gas TUF Medidor de vazão...
Medidores de fluxo de Coriolis para melaço, xarope, chorume, glicose, medição de fluxo de vapor.Comprar medidor de Co...
Accuracy |
±1% reading;±0.5% full range |
Repeatability |
±0.5% of full range |
Turn down ratio |
Normal 100:1; it is decided by calibrated flow range |
Upper Limit of Range |
80 Nm/s (air,20℃,101.33kPa) |
Lower Limit of Range |
0.05Nm/s (air,20℃,101.33kPa) |
Size |
Ø6~ Ø6000 thermal dispersion flow meter |
Pressure Range |
Negative Pressure, 0~1.0MPa,0~1.6MPa,0~2.0MPa,0~3.0MPa |
Medium Temperature |
-20~60℃,60~100℃,100~150℃,150~200℃,200~300℃ |
Medium |
All kinds pure gas or mixed gas with fixed percentage, gas with dust, sand or moisture, corrosive gas |
Sensor Diameter |
Ø3(standard), Ø4 |
Sensor Material |
316SST,Hastelloy,titanium |
Probe Stem Diameter |
Ø19(standard), Ø16, Ø12 |
Probe Stem Material |
316SST,Hastelloy, |
Power supply |
24VDC/400mA or 220VAC/2W |
Output |
4-20mA DC, max load 1000Ω;RS485 |
Display |
LED; four digits instantaneous flow, eight digits totalized flow |
Correction |
16 non-linearity correction |
Type |
Remote type: transmitter + flow totalizer Integral type: transmitter with integral totalizer |
Connection type |
In-line type and plug-in type |
Alarm |
1-2 relay output,3A/220VAC,3A/30VAC,settable |
Protection level |
IP65 |
Explosive proof |
Ia IICT65,ExdII CT4 |
Lifetime |
5 years |
Item |
Code |
Description |
||
Product Code |
SRK-100 |
SRK-100 Series Thermal Mass Flow meter |
||
Pipe size |
DN |
Ø6~ Ø6000 |
||
Construction |
F |
Remote Type |
||
I |
Compact Type |
|||
Sensor Structure *1 |
PI |
Insertion Type |
W |
Weld base |
B |
Base + ball valve |
|||
PL |
In-line Type |
F |
Flange |
|
T |
Thread |
|||
C |
Compression fitting |
|||
Probe Diameter |
19 |
Ø19(standard) |
||
16 |
Ø16 |
|||
12 |
Ø12 |
|||
Probe Material |
6 |
316 |
||
F |
PTFE coated |
|||
Y |
Others |
|||
Explosive Proof |
A0 |
NO |
||
A1 |
With Explosive Proof |
|||
Temperature |
T0 |
-20~60 ℃ |
||
T1 |
60-100℃ |
|||
T2 |
100-150℃ |
|||
T3 |
150-200℃ |
|||
T4 |
200-300℃ |
|||
Pressure |
P0 |
Negative Pressure |
||
P1 |
0-1.0Mpa |
|||
P2 |
0-1.6Mpa |
|||
P3 |
0-2.0Mpa |
|||
P4 |
0-3.0Mpa |
|||
Power Supply |
D |
24VDC |
||
A |
220VAC |
|||
0 |
Other |
|||
Output |
0 |
No output |
||
1 |
4-20mA |
|||
2 |
RS485,Modbus |
|||
3 |
Hart Protocol |
|||
Alarm |
A0 |
No alarm |
||
A1 |
1 alarm relay output |
|||
A2 |
1 alarm relay outputs |
|||
Display |
N |
No display |
||
E |
LED |
Nota:
* 1, Por exemplo: Código PIW --- Medidor de vazão do tipo inserção com base de solda.
entraremos em contato com você dentro de 24 horas.